HomeBox: Notifier SSRF guard misses NAT64 prefixes (64:ff9b::/96, 64:ff9b:1::/48) — generic:// URL reaches cloud metadata on NAT64 egress
Get instant alerts when new vulnerabilities affect homebox - before attackers find them.
HomeBox is a home inventory and organization system. Prior to 0.26.0, the default-on BlockBogonNets and BlockCloudMetadata notifier SSRF protections in backend/internal/sys/validate/notifier_url.go do not inspect IPv4 destinations embedded in the NAT64 prefixes 64:ff9b::/96 and 64:ff9b:1::/48. An authenticated user can submit a generic:// notifier through POST /v1/notifiers or POST /v1/notifiers/test, and on a Homebox instance that egresses through NAT64/DNS64, the gateway can translate an accepted IPv6 destination to cloud metadata, localhost, or another internal IPv4 host. The notifier test path returns delivery result information, and Shoutrrr propagates the response, providing feedback that can disclose retrieved metadata such as temporary credentials. Without NAT64 egress, the crafted IPv6 destination is not routable, but the guard still incorrectly classifies it as safe. This issue is fixed in version 0.26.0.
Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.
No remediation guidance has been written for this CVE yet, and no fixed version or vendor advisory is recorded against it.
SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.
Get alerted
Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.