IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

fw1060.00 ≤ v < fw1060.81
Affected range stops below fw1060.81, so it looks safe — our inference, not a vendor statement
ibm-power-system-e1050-9043-mrx (same device)
fw1060.00 ≤ v < fw1060.81
Affected range stops below fw1060.81, so it looks safe — our inference, not a vendor statement
ibm-power-system-e1080-9080-hex (same device)
fw1110.00 ≤ v < fw1110.31fw1120.00
Affected range stops below fw1110.31, so it looks safe — our inference, not a vendor statement
ibm-power-system-e1150-9043-mru (same device)
fw1110.00 ≤ v < fw1110.31fw1120.00
Affected range stops below fw1110.31, so it looks safe — our inference, not a vendor statement
ibm-power-system-e1180-9080-heu (same device)
fw1060.00 ≤ v < fw1060.81
Affected range stops below fw1060.81, so it looks safe — our inference, not a vendor statement
ibm-power-system-l1022-9786-22h (same device)
fw1060.00 ≤ v < fw1060.81
Affected range stops below fw1060.81, so it looks safe — our inference, not a vendor statement
ibm-power-system-l1024-9786-42h (same device)
fw1110.00 ≤ v < fw1110.31fw1120.00
Affected range stops below fw1110.31, so it looks safe — our inference, not a vendor statement
ibm-power-system-l1122-9856-22h (same device)
fw1110.00 ≤ v < fw1110.31fw1120.00
Affected range stops below fw1110.31, so it looks safe — our inference, not a vendor statement
ibm-power-system-l1124-9856-42h (same device)
fw1060.00 ≤ v < fw1060.81
Affected range stops below fw1060.81, so it looks safe — our inference, not a vendor statement
ibm-power-system-s1012-9028-21b (same device)
fw1060.00 ≤ v < fw1060.81
Affected range stops below fw1060.81, so it looks safe — our inference, not a vendor statement
ibm-power-system-s1014-9105-41b (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (1)

Vendor AdvisoryPatch
Source: cverecord
https://www.ibm.com/support/pages/node/7283219

SSVC — Action Prioritization

SSVCNo known exploitNot automatablePartial impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

7.9HIGHibm
Attack Vector
LOCAL
Complexity
LOW
Privileges
HIGH
User Interaction
NONE
Scope
CHANGED
Confidentiality
HIGH
Integrity
NONE
Availability
HIGH
Vector?

Quick Info

StatusANALYZED
CWE
CWE-863

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card