CVE-2024-48985

HIGH
7.5
CVSS Score
Published: November 20, 2024 at 12:00 AM UTC
Updated: June 17, 2026 at 07:59 AM UTC
2 products affected across 2 vendorsMbedMbed

Using N/A by N/A?

Get instant alerts when new vulnerabilities affect N/A - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH7.5
Exploit prediction
EPSS 0.4%
SSVC
No known exploit

Description

An issue was discovered in MBed OS 6.16.0. During processing of HCI packets, the software dynamically determines the length of the packet data by reading 2 bytes from the packet data. A buffer is then allocated to contain the entire packet, the size of which is calculated as the length of the packet body determined earlier and the header length. If the allocate fails because the specified packet is too large, no exception handling occurs and hciTrSerialRxIncoming continues to write bytes into the 4-byte large temporary header buffer, leading to a buffer overflow. This can be leveraged into an arbitrary write by an attacker. It is possible to overwrite the pointer to the buffer that is supposed to receive the contents of the packet body but which couldn't be allocated. One can then overwrite the state variable used by the function to determine which step of the parsing process is currently being executed. This advances the function to the next state, where it proceeds to copy data to that arbitrary location. The packet body is then written wherever the corrupted data pointer is pointing.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

Patch and advisory references

SSVC — Action Prioritization

SSVCNo known exploitAutomatablePartial impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

7.5HIGHCISA-ADP
Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
NONE
Integrity
HIGH
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-120

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card