CVE-2024-43659

Plaintext default credentials in firmware

HIGH
7.2
CVSS Score
Published: January 9, 2025 at 07:56 AM UTC
Updated: June 17, 2026 at 07:51 AM UTC
1 product affected across 1 vendorFirmware for AC models

Using Iocharger firmware for AC models by Iocharger?

Get instant alerts when new vulnerabilities affect Iocharger firmware for AC models - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH7.2
Exploit prediction
EPSS 0.8%
SSVC
No known exploit

Description

After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v < 25010801
Affected range stops below 25010801, so it looks safe — our inference, not a vendor statement

Remediation

No guide yet

No remediation guidance has been written for this CVE yet, and no fixed version or vendor advisory is recorded against it.

SSVC — Action Prioritization

SSVCNo known exploitNot automatableTotal impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

7.2HIGHCISA-ADP
Attack Vector
NETWORK
Complexity
LOW
Privileges
HIGH
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH
Vector?

Quick Info

StatusDEFERRED
CWE
CWE-256CWE-1391CWE-1393

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.