CVE-2023-23915

MEDIUM
6.5
CVSS Score
Published: February 23, 2023 at 12:00 AM UTC
Updated: October 24, 2026 at 01:10 PM UTC
8 products affected across 3 vendorsActive IQ Unified ManagerH700S FirmwareH410S Firmware· also runs on 4 platforms

Using https://github.com/curl/curl by N/A?

Get instant alerts when new vulnerabilities affect https://github.com/curl/curl - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
MEDIUM6.5
Exploit prediction
EPSS 0.9%
SSVC
No known exploit

Description

A cleartext transmission of sensitive information vulnerability exists in curl <v7.88.0 that could cause HSTS functionality to behave incorrectly when multiple URLs are requested in parallel. Using its HSTS support, curl can be instructed to use HTTPS instead of using an insecure clear-text HTTP step even when HTTP is provided in the URL. This HSTS mechanism would however surprisingly fail when multiple transfers are done in parallel as the HSTS cache file gets overwritten by the most recentlycompleted transfer. A later HTTP-only transfer to the earlier host name would then *not* get upgraded properly to HSTS.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

7.77.0 ≤ v < 7.88.0
Vendor states this is fixed in 7.88.0 (unaffected)
All versions
netapp-h300s (same device)
All versions
netapp-h410s (same device)
All versions
netapp-h500s (same device)
All versions
netapp-h700s (same device)
8.2.0 ≤ v < 8.2.129.0.0 ≤ v < 9.0.69.1.0
Affected range stops below 8.2.12, so it looks safe — our inference, not a vendor statement
Affected range stops below 9.0.6, so it looks safe — our inference, not a vendor statement

Runs on — not affected

The affected product only carries this flaw when running on these platforms. The platforms themselves are not vulnerable.

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

Patch and advisory references

SSVC — Action Prioritization

SSVCNo known exploitAutomatablePartial impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

6.5MEDIUMCISA-ADP
Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
LOW
Integrity
LOW
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-319

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card