CVE-2022-42784

MEDIUM
6.8
CVSS Score
Published: December 12, 2023 at 10:02 AM UTC
Updated: June 17, 2026 at 05:05 AM UTC
34 products affected across 1 vendor6AG1052 1HB08 7BA1 Firmware6AG1052 1CC08 7BA1 Firmware6AG1052 2MD08 7BA1 Firmware

Using LOGO! 12/24RCE by Siemens?

Get instant alerts when new vulnerabilities affect LOGO! 12/24RCE - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
MEDIUM6.8
Exploit prediction
EPSS 0.2%

Description

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v ≤ 8.3
siemens-6ag1052-1cc08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-1fb08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-1hb08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-1md08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-2cc08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-2fb08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-2hb08-7ba1 (same device)
v ≤ 8.3
siemens-6ag1052-2md08-7ba1 (same device)
v ≤ 8.3
siemens-6ed1052-1cc08-0ba1 (same device)
v ≤ 8.3
siemens-6ed1052-1fb08-0ba1 (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

CVSS

Attack Vector
PHYSICAL
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-1319NVD-CWE-Other

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card