CVE-2022-41972

Contiki-NG contains NULL Pointer Dereference in BLE L2CAP module

MEDIUM
6.5
CVSS Score
Published: December 16, 2022 at 05:37 PM UTC
Updated: June 17, 2026 at 05:04 AM UTC
1 product affected across 1 vendorContiki-NG

Using contiki-ng by contiki-ng?

Get instant alerts when new vulnerabilities affect contiki-ng - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
MEDIUM6.5
Exploit prediction
EPSS 0.2%
SSVC
No known exploit

Description

Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. Versions prior to 4.9 contain a NULL Pointer Dereference in BLE L2CAP module. The Contiki-NG operating system for IoT devices contains a Bluetooth Low Energy stack. An attacker can inject a packet in this stack, which causes the implementation to dereference a NULL pointer and triggers undefined behavior. More specifically, while processing the L2CAP protocol, the implementation maps an incoming channel ID to its metadata structure. In this structure, state information regarding credits is managed through calls to the function input_l2cap_credit in the module os/net/mac/ble/ble-l2cap.c. Unfortunately, the input_l2cap_credit function does not check that the metadata corresponding to the user-supplied channel ID actually exists, which can lead to the channel variable being set to NULL before a pointer dereferencing operation is performed. The vulnerability has been patched in the "develop" branch of Contiki-NG, and will be included in release 4.9. Users can apply the patch in Contiki-NG pull request #2253 as a workaround until the new package is released.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

SSVC — Action Prioritization

SSVCNo known exploitNot automatablePartial impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

Attack Vector
ADJACENT_NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
NONE
Integrity
NONE
Availability
HIGH
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-476

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.