CVE-2021-45460

HIGH
8.1
CVSS Score
Published: January 11, 2022 at 11:27 AM UTC
Updated: June 17, 2026 at 04:13 AM UTC
2 products affected across 1 vendorSicam Pq Analyzer FirmwareSICAM PQ Analyzer

Using SICAM PQ Analyzer by Siemens?

Get instant alerts when new vulnerabilities affect SICAM PQ Analyzer - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH8.1
Exploit prediction
EPSS 0.8%

Description

A vulnerability has been identified in SICAM PQ Analyzer (All versions < V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system ("backdoors") or cause a denial of service.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v < 3.18
Affected range stops below 3.18, so it looks safe — our inference, not a vendor statement
siemens-sicam-pq-analyzer (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (1)

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
NONE
Integrity
HIGH
Availability
HIGH
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-428