Junos OS: QFX5000 Series: Traffic from the network internal to the device (128.0.0.0) may be forwarded to egress interfaces.
Get instant alerts when new vulnerabilities affect Junos OS - before attackers find them.
Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It was discovered that packets utilizing these IP addresses may egress an QFX5000 Series switch, leaking configuration information such as heartbeats, kernel versions, etc. out to the Internet, leading to an information exposure vulnerability. This issue affects Juniper Networks Junos OS on QFX5110, QFX5120, QFX5200, QFX5210 Series, and QFX5100 with QFX 5e Series image installed: All versions prior to 17.3R3-S12; 18.1 versions prior to 18.1R3-S13; 18.3 versions prior to 18.3R3-S5; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2;
Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.
No remediation guidance has been written for this CVE yet. What the record does show:
Patch and advisory references
Get alerted
Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.