CVE-2021-22813

MEDIUM
6.1
CVSS Score
Published: January 28, 2022 at 07:09 PM UTC
Updated: June 17, 2026 at 03:37 AM UTC
55 products affected across 1 vendorNetwork Management Card 2 FirmwareNetwork Management Card 3 FirmwareUPS Network Management Card 2

Using N/A by N/A?

Get instant alerts when new vulnerabilities affect N/A - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
MEDIUM6.1
Exploit prediction
EPSS 0.7%

Description

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v ≤ 6.9.6v ≤ 6.9.8
schneider-electric-ap9922-battery-management-system (environment) · schneider-electric-apc-rack-power-distribution-units (environment) · schneider-electric-galaxy-3500 (environment) · schneider-electric-galaxy-g7x (environment) · schneider-electric-galaxy-g9kchu (environment) · schneider-electric-galaxy-gcxsa (environment) · schneider-electric-galaxy-gfc (environment) · schneider-electric-galaxy-gvmsa (environment) · schneider-electric-galaxy-gvmts (environment) · schneider-electric-galaxy-gvxts (environment) · schneider-electric-galaxy-rpp-grppip2x84 (environment) · schneider-electric-gutor-gvx (environment) · schneider-electric-gutor-sxw (environment) · schneider-electric-netbotz-nbrk0250 (environment) · schneider-electric-pd40e5ek20-m (environment) · schneider-electric-pd40f6fk1-m (environment) · schneider-electric-pd40g6fk1-m (environment) · schneider-electric-pd40h5ek20-m (environment) · schneider-electric-pd40l6fk1-m (environment) · schneider-electric-pd60f6fk1 (environment) · schneider-electric-pd60g6fk1 (environment) · schneider-electric-pd60l6fk1 (environment) · schneider-electric-pdpb150g6f (environment) · schneider-electric-pdpm138h-5u (environment) · schneider-electric-pdpm138h-r (environment) · schneider-electric-pdpm144f (environment) · schneider-electric-pdpm150g6f (environment) · schneider-electric-pdpm150l6f (environment) · schneider-electric-pdpm175g6h (environment) · schneider-electric-pdpm277h (environment) · schneider-electric-pdpm288g6h (environment) · schneider-electric-pdpm72f-5u (environment) · schneider-electric-pdrppnx10 (environment) · schneider-electric-pdrppnx10m (environment) · schneider-electric-pmm400-ala (environment) · schneider-electric-pmm400-alax (environment) · schneider-electric-pmm400-cub (environment) · schneider-electric-pmm500-ala (environment) · schneider-electric-pmm500-alax (environment) · schneider-electric-pmm500-cub (environment) · schneider-electric-rack-automatic-transfer-switches (environment) · schneider-electric-single-phase-symmetra (environment) · schneider-electric-smart-ups (environment) · schneider-electric-symmetra-px-100 (environment) · schneider-electric-symmetra-px-160 (environment) · schneider-electric-symmetra-px-20 (environment) · schneider-electric-symmetra-px-250 (environment) · schneider-electric-symmetra-px-40 (environment) · schneider-electric-symmetra-px-48 (environment) · schneider-electric-symmetra-px-500 (environment) · schneider-electric-symmetra-px-96 (environment) · schneider-electric-network-management-card-2 (same device)
v ≤ 1.4.0v ≤ 1.4.2.1
schneider-electric-apc-rack-power-distribution-units (environment) · schneider-electric-galaxy-3500 (environment) · schneider-electric-single-phase-symmetra (environment) · schneider-electric-smart-ups (environment) · schneider-electric-network-management-card-3 (same device)
All versions
All versions

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (1)

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
REQUIRED
Scope
CHANGED
Confidentiality
LOW
Integrity
LOW
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-79

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card