CVE-2021-22701

MEDIUM
4.5
CVSS Score
Published: February 19, 2021 at 03:15 PM UTC
Updated: June 17, 2026 at 03:37 AM UTC
22 products affected across 1 vendorPowerlogic ION8650 FirmwarePowerlogic ION7400 FirmwarePowerlogic PM8000 Firmware

Using PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) by N/A?

Get instant alerts when new vulnerabilities affect PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
MEDIUM4.5
Exploit prediction
EPSS 0.3%
SSVC
No known exploit

Description

A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v < 3.0.0
Affected range stops below 3.0.0, so it looks safe — our inference, not a vendor statement
schneider-electric-powerlogic-ion7410 (environment) · schneider-electric-powerlogic-ion7400 (same device)
All versions
schneider-electric-powerlogic-ion7650 (same device)
All versions
schneider-electric-powerlogic-ion8300 (same device)
All versions
schneider-electric-powerlogic-ion8400 (same device)
All versions
schneider-electric-powerlogic-ion8500 (same device)
All versions
schneider-electric-powerlogic-ion8600 (same device)
v ≤ 4.31.2
schneider-electric-powerlogic-ion8650 (same device)
All versions
schneider-electric-powerlogic-ion8800 (same device)
v < 3.0.0
Affected range stops below 3.0.0, so it looks safe — our inference, not a vendor statement
schneider-electric-powerlogic-ion9000 (same device)
v < 3.0.0
Affected range stops below 3.0.0, so it looks safe — our inference, not a vendor statement
schneider-electric-powerlogic-pm8000 (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (1)

SSVC — Action Prioritization

SSVCNo known exploitNot automatablePartial impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
HIGH
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality
NONE
Integrity
HIGH
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-352

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card