CVE-2020-7548

CRITICAL
9.8
CVSS Score
Published: December 1, 2020 at 02:45 PM UTC
Updated: June 17, 2026 at 03:24 AM UTC
16 products affected across 1 vendorACTI9 Smartlink El B FirmwareACTI9 Powertag Link FirmwareACTI9 Smartlink Si D Firmware

Using Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) by N/A?

Get instant alerts when new vulnerabilities affect Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
CRITICAL9.8
Exploit prediction
EPSS 1%

Description

A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v < 001.008.007
Affected range stops below 001.008.007, so it looks safe — our inference, not a vendor statement
schneider-electric-acti9-powertag-link (same device)
v < 001.008.007
Affected range stops below 001.008.007, so it looks safe — our inference, not a vendor statement
schneider-electric-acti9-powertag-link-hd (same device)
v < 1.2.1
Affected range stops below 1.2.1, so it looks safe — our inference, not a vendor statement
schneider-electric-acti9-smartlink-el-b (same device)
v < 002.004.002
Affected range stops below 002.004.002, so it looks safe — our inference, not a vendor statement
schneider-electric-acti9-smartlink-si-b (same device)
v < 002.004.002
Affected range stops below 002.004.002, so it looks safe — our inference, not a vendor statement
schneider-electric-acti9-smartlink-si-d (same device)
v < 1.5.0
Affected range stops below 1.5.0, so it looks safe — our inference, not a vendor statement
schneider-electric-wiser-energy (same device)
v < 1.5.0
Affected range stops below 1.5.0, so it looks safe — our inference, not a vendor statement
schneider-electric-wiser-link (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (1)

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-330

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card