CVE-2020-17437

HIGH
8.2
CVSS Score
Published: December 11, 2020 at 10:24 PM UTC
Updated: June 17, 2026 at 02:58 AM UTC
20 products affected across 3 vendorsUipOpen IscsiSentron 3VA COM100 Firmware· also runs on 1 platform

Using N/A by N/A?

Get instant alerts when new vulnerabilities affect N/A - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH8.2
Exploit prediction
EPSS 3%

Description

An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v < 4.4.1
Affected range stops below 4.4.1, so it looks safe — our inference, not a vendor statement
siemens-sentron-3va-com100 (same device)
v < 4.4.1
Affected range stops below 4.4.1, so it looks safe — our inference, not a vendor statement
siemens-sentron-3va-com800 (same device)
v < 4.0
Affected range stops below 4.0, so it looks safe — our inference, not a vendor statement
siemens-sentron-3va-dsp800 (same device)
All versions
siemens-sentron-pac2200-clp (same device)
v < 3.2.2
Affected range stops below 3.2.2, so it looks safe — our inference, not a vendor statement
siemens-sentron-pac2200 (same device)
v < 2.4.7
Affected range stops below 2.4.7, so it looks safe — our inference, not a vendor statement
siemens-sentron-7km-pac3200 (same device)
v < 3.2.2
Affected range stops below 3.2.2, so it looks safe — our inference, not a vendor statement
siemens-sentron-pac3200t (same device)
v < 3.2.0
Affected range stops below 3.2.0, so it looks safe — our inference, not a vendor statement
siemens-sentron-pac3220 (same device)
v < 2.3.0
Affected range stops below 2.3.0, so it looks safe — our inference, not a vendor statement
siemens-sentron-pac4200 (same device)

Runs on — not affected

The affected product only carries this flaw when running on these platforms. The platforms themselves are not vulnerable.

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (3)

x_refsource_MISCThird Party AdvisoryUS Government Resource
https://us-cert.cisa.gov/ics/advisories/icsa-20-343-01
x_refsource_MISCThird Party AdvisoryUS Government Resource
https://www.kb.cert.org/vuls/id/815128

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
LOW
Integrity
NONE
Availability
HIGH
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-787

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card