CVE-2019-25678

C4G BLIS 3.4 SQL Injection via users_select.php

HIGH
7.5
CVSS Score
Published: April 5, 2026 at 08:45 PM UTC
Updated: July 24, 2026 at 10:20 PM UTC
2 products affected across 2 vendorsComputing for Good 's Basic Laboratory Information SystemBasic Laboratory Information System

Using Basic Laboratory Information System by C4G?

Get instant alerts when new vulnerabilities affect Basic Laboratory Information System - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH7.5
Exploit prediction
EPSS 0.3%
SSVC
PoC

Description

C4G Basic Laboratory Information System 3.4 contains multiple SQL injection vulnerabilities that allow unauthenticated attackers to execute arbitrary SQL commands by injecting malicious code through the site parameter. Attackers can send GET requests to the users_select.php endpoint with crafted SQL payloads to extract sensitive database information including patient records and system credentials.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

Remediation

No guide yet

No remediation guidance has been written for this CVE yet, and no fixed version or vendor advisory is recorded against it.

SSVC — Action Prioritization

SSVCPoCAutomatablePartial impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
NONE
Availability
NONE
Vector?

Quick Info

StatusANALYZED
CWE
CWE-306CWE-89

Get alerted