37 products affected across 1 vendorScalance X408-2 FirmwareScalance X 300 FirmwareScalance Xr 300WG Firmware

Using SCALANCE X204RNA (HSR) by Siemens?

Get instant alerts when new vulnerabilities affect SCALANCE X204RNA (HSR) - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH8.6
Exploit prediction
EPSS 1%

Description

A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

All versions
siemens-scalance-x-200rna (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-x-300 (same device)
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-x408-2 (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-xr-300 (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-xr-300wg (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-siplus-net-csm-1277 (same device)
siemens-scalance-x204rna (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
LOW
Integrity
HIGH
Availability
LOW