CVE-2019-13924

MEDIUM
5.4
CVSS Score
Published: February 11, 2020 at 12:00 AM UTC
Updated: June 17, 2026 at 02:17 AM UTC
22 products affected across 1 vendorScalance X 300 FirmwareScalance X 200IRT FirmwareScalance Xp 200 Firmware

Using SCALANCE S602 by Siemens?

Get instant alerts when new vulnerabilities affect SCALANCE S602 - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
MEDIUM5.4
Exploit prediction
EPSS 0.8%

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

All versions
siemens-scalance-x-200irt (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-x-300 (same device)
v < 5.2.4
Affected range stops below 5.2.4, so it looks safe — our inference, not a vendor statement
siemens-scalance-xb-200 (same device)
v < 5.2.4
Affected range stops below 5.2.4, so it looks safe — our inference, not a vendor statement
siemens-scalance-xc-200 (same device)
v < 5.2.4
Affected range stops below 5.2.4, so it looks safe — our inference, not a vendor statement
siemens-scalance-xf-200 (same device)
v < 5.2.4
Affected range stops below 5.2.4, so it looks safe — our inference, not a vendor statement
siemens-scalance-xp-200 (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-xr-300 (same device)
v < 4.1.3
Affected range stops below 4.1.3, so it looks safe — our inference, not a vendor statement
siemens-scalance-xr-300wg (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality
LOW
Integrity
LOW
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-693CWE-1021

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card