41 products affected across 1 vendorImp319-1 FirmwareImp219-1e FirmwareImp219-1er Firmware

Using Pelco Sarix Professional by Schneider Electric SE?

Get instant alerts when new vulnerabilities affect Pelco Sarix Professional - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
CRITICAL9.8
Exploit prediction
EPSS 3%

Description

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-ibp1110-1er (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-ibp219-1er (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-ibp319-1er (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-ibp519-1er (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-ibps110-1er (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-imp1110-1 (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-imp1110-1e (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-imp1110-1er (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-imp219-1 (same device)
v < 3.29.67
Affected range stops below 3.29.67, so it looks safe — our inference, not a vendor statement
schneider-electric-imp219-1e (same device)

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (1)

CVSS

Attack Vector
NETWORK
Complexity
LOW
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-120

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card