Get instant alerts when new vulnerabilities affect N/A - before attackers find them.
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have a timeout policy to wait for 5 minutes in case 30 incorrect password attempts are detected using the Web and HTTP API interface provided by the device. However, if the same brute force attempt is performed using the ONVIF specification (which is supported by the same binary) then there is no account lockout or timeout executed. This can allow an attacker to circumvent the account protection mechanism and brute force the credentials. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that performs the credential check in the binary for the ONVIF specification. If one opens this binary in IDA-pro one will notice that this follows a ARM little endian format. The function at address 00671618 in IDA pro is parses the WSSE security token header. The sub_ 603D8 then performs the authentication check and if it is incorrect passes to the function sub_59F4C which prints the value "Sender not authorized."
Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.
No remediation guidance has been written for this CVE yet, and no fixed version or vendor advisory is recorded against it.
Get alerted
Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.