CVE-2017-6602

N/A
Published: April 7, 2017 at 05:00 PM UTC
Updated: June 17, 2026 at 01:22 AM UTC
5 products affected across 1 vendorUnified Computing SystemFirepower Extensible Operating SystemUnified Computing System Manager

Using Cisco UCS Manager, Cisco Firepower 4100 Series NGFW, and Cisco Firepower 9300 Security Appliance by N/A?

Get instant alerts when new vulnerabilities affect Cisco UCS Manager, Cisco Firepower 4100 Series NGFW, and Cisco Firepower 9300 Security Appliance - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
N/A
Exploit prediction
EPSS 0.8%

Description

A vulnerability in the CLI of Cisco Unified Computing System (UCS) Manager, Cisco Firepower 4100 Series Next-Generation Firewall (NGFW), and Cisco Firepower 9300 Security Appliance could allow an authenticated, local attacker to perform a command injection attack. More Information: CSCvb66189 CSCvb86775. Known Affected Releases: 2.0(1.68) 3.1(1k)A. Known Fixed Releases: 92.2(1.101) 92.1(1.1742) 92.1(1.1658) 2.1(1.38) 2.0(1.107) 2.0(1.87) 1.1(4.148) 1.1(4.138).

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

CVSS

Confidentiality
PARTIAL
Integrity
PARTIAL
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-78

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card