CVE-2017-10723

N/A
Published: June 17, 2019 at 09:32 PM UTC
Updated: June 17, 2026 at 01:00 AM UTC
2 products affected across 1 vendorEndoscope Camera FirmwareEndoscope Camera

Using N/A by N/A?

Get instant alerts when new vulnerabilities affect N/A - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
N/A
Exploit prediction
EPSS 3%

Description

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries. The firmware contains binary uvc_stream that is the UDP daemon which is responsible for handling all the UDP requests that the device receives. The client application sends a UDP request to change the Wi-Fi name which contains the following format: "SETCMD0001+0001+[2 byte length of wifiname]+[Wifiname]. This request is handled by "control_Dev_thread" function which at address "0x00409AE0" compares the incoming request and determines if the 10th byte is 01 and if it is then it redirects to 0x0040A74C which calls the function "setwifiname". The function "setwifiname" uses a memcpy function but uses the length of the payload obtained by using strlen function as the third parameter which is the number of bytes to copy and this allows an attacker to overflow the function and control the $PC value.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

All versions
ishekar-endoscope-camera (same device)
All versions

Remediation

No guide yet

No remediation guidance has been written for this CVE yet, and no fixed version or vendor advisory is recorded against it.

CVSS

Confidentiality
PARTIAL
Integrity
PARTIAL
Availability
PARTIAL
Vector?