CVE-2017-10721

N/A
Published: June 17, 2019 at 09:19 PM UTC
Updated: June 17, 2026 at 01:00 AM UTC
2 products affected across 1 vendorEndoscope Camera FirmwareEndoscope Camera

Using N/A by N/A?

Get instant alerts when new vulnerabilities affect N/A - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
N/A
Exploit prediction
EPSS 2%

Description

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has Telnet functionality enabled by default. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

All versions
ishekar-endoscope-camera (same device)
All versions

Remediation

No guide yet

No remediation guidance has been written for this CVE yet, and no fixed version or vendor advisory is recorded against it.

CVSS

Confidentiality
NONE
Integrity
PARTIAL
Availability
NONE
Vector?

Quick Info

StatusMODIFIED
CWE
CWE-284

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card