CVE-2017-0148

HIGH
8.1
CVSS Score
Published: March 17, 2017 at 12:00 AM UTC
Updated: June 17, 2026 at 12:57 AM UTC
27 products affected across 2 vendorsServer Message BlockVersant Kpcr Molecular System FirmwareTissue Preparation System Firmware

Using Windows SMB by Microsoft Corporation?

Get instant alerts when new vulnerabilities affect Windows SMB - before attackers find them.

Real-time alertsTrack your software stackFree plan available
Severity
HIGH8.1
Exploitation
CISA KEV
Exploit prediction
EPSS 99%
SSVC
Active

Actively Exploited

CISA Known Exploited Vulnerabilities (KEV) Catalog

EPSS Score99.4%

EPSS (Exploit Prediction Scoring System) estimates a 99.4% chance this CVE is exploited in the wild within the next 30 days — higher than 100% of all CVEs. It complements CVSS: a high EPSS on a mid-severity CVE can still be urgent.

The SMBv1 server in Microsoft allows remote attackers to execute arbitrary code via crafted packets.

Required Action
Apply updates per vendor instructions.
Ransomware Use
Known
Added to KEV
Apr 6, 2022
Remediation Due
Apr 27, 2022
1643 days overdue

Description

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0145, and CVE-2017-0146.

Affected

Our own answer: ranges merged, affected separated from platform-only, with confidence and review flags.

microsoft-windows-10-1507 (environment) · microsoft-windows-10-1511 (environment) · microsoft-windows-10-1607 (environment) · microsoft-windows-7 (environment) · microsoft-windows-8-1 (environment) · microsoft-windows-rt-8-1 (environment) · microsoft-windows-server-2008 (environment) · microsoft-windows-server-2012 (environment) · microsoft-windows-server-2016 (environment) · microsoft-windows-vista (environment)
siemens-acuson-p300 (same device)
siemens-acuson-p500 (same device)
4.0 ≤ v < 4.0e5.0a
Affected range stops below 4.0e, so it looks safe — our inference, not a vendor statement
siemens-acuson-sc2000 (same device)
siemens-acuson-x700 (same device)
4.0 ≤ v ≤ 4.0e5.0a
siemens-syngo-sc2000 (same device)
All versions
siemens-tissue-preparation-system (same device)
All versions
siemens-versant-kpcr-molecular-system (same device)
All versions
siemens-versant-kpcr-sample-prep (same device)
All versions

Remediation

No guide yet

No remediation guidance has been written for this CVE yet. What the record does show:

References (11)

VDB Entryx_refsource_BIDBroken LinkThird Party Advisory
http://www.securityfocus.com/bid/96706
VDB Entryx_refsource_SECTRACKBroken LinkThird Party Advisory
http://www.securitytracker.com/id/1037991
x_refsource_MISCThird Party AdvisoryUS Government Resource
https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02

SSVC — Action Prioritization

SSVCActiveNot automatableTotal impact

SSVC signals action urgency (what to patch first), separate from CVSS which measures severity.

CVSS

8.1HIGHCISA-ADP
Attack Vector
NETWORK
Complexity
HIGH
Privileges
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH
Vector?

Quick Info

StatusANALYZED
CWE
NVD-CWE-noinfoCWE-20

Get alerted

Stop reading CVE feeds looking for your own stack

Track the products you run and VulnTracker tells you when a new CVE affects them — with what is known about fixing it, and nothing about the rest.

Free plan, no card